In stock
Item number: 19100090
Pay safe and fast with:
Orcon's decentralised heat recovery unit is specially designed to create an optimal indoor climate. CO2 levels are often too high in many offices and other spaces. This can be prevented by installing a decentralised heat recovery unit. Each individual room is thus provided with healthy and fresh air and contributes to an optimal indoor climate. Orcon's HRT units are among the smartest on the market. They have several sensors and an integrated smart controller and display.
The WTU-EC-TA is equipped with heat recovery. In this way, the WTU-EC-TA heats up the cold air from outside with the warm air from inside. In order to obtain cool air in the summer and not to heat up the room further, the unit is equipped as standard with a bypass. This option ensures that cold, filtered air is blown in from outside during the night. Besides recovering heat, the system also recovers humidity by means of an enthalpy heat exchanger. This keeps the temperature and relative humidity at a comfortable level.
Attention: Without control (or position switch for perilex models), the ventilation unit will only be able to operate at low speed.
Orcon also offers software via their E-tool:
| Brand | Orcon |
| Category | Heat recovery choice aid |
| GTIN | 8718403860450 |
| Manufacturer's item number | 15100045 |
| Article number | 19220064 |
| Category code | 17 |
| Device emplacement | Indoor positioning |
| Housing material | Steel, lined |
| Max. air volume at 50 Pa | 700 m³/h |
| Max. air volume at 100 Pa | 640 m³/h |
| Max. air volume at 150 Pa | 600 m³/h |
| Max. air volume at 200 Pa | 520 m³/h |
| Max. air volume at 250 Pa | 440 m³/h |
| Max. air volume at 300 Pa | 360 m³/h |
| Fan type | Direct |
| Type of motor | Electronically commutated (EC) |
| Heat recovery by | Counter current unit |
| Type of cooling coil | None |
| Type of heating coil | None |
| Change-over system | No |
| With bypass | Yes |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Efficiency supply filter according to ISO 16890-1:2016 | 45 % |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 45 % |
| With condensate drain | Yes |
| Frost protection circuit | No |
| With constant pressure control | No |
| With constant volume flow control | No |
| Connection voltage | 1x 230 V AC |
| Electrical connection | Connection cable with plug |
| With thermal overload protection | Yes |
| Power consumption | 0.218 kW |
| Thermal efficiency | 82 % |
| Suitable for electronic control | Yes |
| Suitable for low-current control | Yes |
| With rotational speed/frequency control | Yes |
| Suitable for transformer control | No |
| Nominal duct diameter, outdoor connection | 200 mm |
| Connection | Flange |
| Length | 1325 mm |
| Width | 934 mm |
| Height | 355 mm |
| With roof plate | No |
| With support frame | No |
| Weight | 58 kg |
| With enthalpy exchanger | No |