Item number: 19130111
Pay safe and fast with:
The new HRC 300 MaxComfort is Orcon’s latest heat recovery ventilation (HRV) unit, replacing the HRC BRPH-15. Compared to its predecessor, the HRC MaxComfort is up to 60% more energy-efficient and achieves a thermal efficiency of up to 99.3%! The unit delivers a maximum airflow of 300 m³/h at 150Pa and operates with very low noise levels. Additionally, the Orcon MaxComfort comes standard with an integrated preheater.
TIP: Using the dip switches, the HRV unit can be configured for 300 m³/h at 200 Pa.
Orcon’s HRV is one of the smartest heat recovery units on the market. Thanks to its numerous integrated sensors, the device precisely measures current indoor conditions and can adjust accordingly. This demand-driven ventilation prevents unnecessary energy consumption. The HRC 300 is equipped with the following integrated sensors:
With these 13 built-in sensors, airflow can be balanced with an accuracy up to 1%. Furthermore, the sensors enable even better control in various demand-driven scenarios such as bypass, frost protection, shower, and cooking modes. Additionally, up to 20 extra RF sensors or RF controls can be connected to the unit.
The Orcon 300 MaxComfort HRV offers exceptional ease of installation. The unit is suitable for both left- and right-side installation by mounting the controls, filters, and front panel on the opposite side of the device. Moreover, ventilation ducts can be connected either on the side or the top, and the unit supports both Perilex and standard earthed plugs. This means there is one model for all applications! The Ecomax is supplied with a standard earthed plug, with the Perilex plug available separately.
Both left and right versions
The Orcon HRC MaxComfort can be installed in two configurations. By default, the unit is delivered in the "left" configuration, with the domestic connections on the left side and outdoor connections on the right side. However, this is easily reversible: by detaching the front and back panels, the unit can be flipped! For more details, please refer to the installation manual.
Additional features of the Orcon HRC 300 Healthline MaxComfort:There is a subsidy available for the purchase of a heat pump under the Investment Subsidy for Sustainable Energy (ISDE). For more information about subsidised products, general conditions, subsidy amounts, and the correct notification code, please consult the RVO's Notification Code List for Ventilation Units.
| Brand | Orcon |
| Category | All MVHR units |
| GTIN | 8718403860115 |
| Manufacturer's item number | 22000085 |
| Article number | 19220030 |
| Category code | 16 |
| Heat recovery by | Cross-counter-flow unit |
| Housing material | Plastic |
| Housing material quality | Expanded polypropylene (EPP) |
| Material heat exchanger | Plastic |
| Suitable for wall mounting | Yes |
| Suitable for ceiling mounting | No |
| Suitable for floor mounting | Yes |
| Suitable for mounting in suspended ceiling | No |
| Suitable for mounting in an attic | Yes |
| Left/right orientation reversible | Yes |
| Max. air volume at 50 Pa | 300 m³/h |
| Max. air volume at 100 Pa | 300 m³/h |
| Max. air volume at 150 Pa | 300 m³/h |
| Max. air volume at 200 Pa | 300 m³/h |
| Max. air volume at 250 Pa | 300 m³/h |
| Max. air volume at 300 Pa | 300 m³/h |
| Power consumption at max. air volume at 100 Pa | 65 W |
| Thermal efficiency at 70% air volume at 50 Pa | 94 % |
| Type of motor | Electronically commutated (EC) |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Number of phases | 1 |
| Fuse size of the device | 6 A |
| With thermal overload protection | Yes |
| Electrical connection | Connecting cable with plug with protective contact |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Type of switch | Other |
| With digital display | No |
| With wired control unit | No |
| Suitable for wired control unit | No |
| With wireless remote control | No |
| Suitable for wireless remote control | Yes |
| Supporting protocol for Modbus | Yes |
| Operation by app | No |
| With zone controller | No |
| Suitable for zone controller | Yes |
| With heating element | Yes |
| With volatile organic compound (VOC) sensor | No |
| Suitable for extra VOC sensor | No |
| With external humidity (RH) sensor | No |
| With internal humidity (RH) sensor | Yes |
| Suitable for (extra) humidity (RH) sensor | Yes |
| With internal carbon dioxide (CO2) sensor | No |
| Suitable for (extra) carbon dioxide (CO2) sensor | Yes |
| Suitable for central heating boiler connection | No |
| With bypass | Yes |
| With constant pressure control | No |
| With constant volume flow control | Yes |
| Type of frost protection | Other |
| Nominal duct diameter (min) | 150 mm |
| Nominal duct diameter (max) | 150 mm |
| Connections outdoor air side | Insert end |
| Connections residential side | Insert end |
| Residential connection, underside | No |
| Residential connection, left side | Yes |
| Residential connection, right side | Yes |
| Residential connection, top | Yes |
| Roof connection, side | Yes |
| Roof connection, top | Yes |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Efficiency supply filter according to ISO 16890-1:2016 | 70 % |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Height | 888 mm |
| Width | 760 mm |
| Depth | 600 mm |
| Degree of protection (IP) | IP31 |
| Weight | 33.7 kg |
| Energy label | A+ |
| Connection type | connection left right |
| With enthalpy exchanger | No |
| Plug type | Euro plug |