In stock
Item number: 19100090
Pay safe and fast with:
Orcon's decentralised heat recovery unit is specially developed for creating an optimal indoor climate. In many offices and other spaces, the CO2 values are often too high. This can be prevented by installing a decentralised heat recovery unit. Each individual room is thus provided with healthy and fresh air and contributes to an optimal indoor climate. Orcon's MVHR units are among the smartest on the market. They have various sensors and an integrated smart controller and display.
The WTU- EC-E is equipped with heat recovery. Therefore, the WTU-EC-E heats the cold air from outside with the warm air from inside. In order to obtain cool air in the summer and to not heat up the room further, the unit is equipped as standard with a bypass. This option ensures that cold, filtered air is brought in from outside during the night. Besides recovering heat, the system also recovers humidity by means of an enthalpy heat exchanger. This keeps the temperature and relative humidity at a comfortable level.
Orcon also offers software via their E-tool:
| Brand | Orcon |
| Category | Orcon WTU ventilation units |
| GTIN | 8718403862553 |
| Manufacturer's item number | 15100002 |
| Article number | 19220060 |
| Category code | 17 |
| Length | 907 mm |
| Connection | Flange |
| Width | 750 mm |
| Height | 296 mm |
| Housing material | Steel, lined |
| Heat recovery by | Cross-counter-flow unit |
| Max. air volume at 100 Pa | 310 m³/h |
| Max. air volume at 200 Pa | 265 m³/h |
| Electrical connection | Connection cable with plug |
| Type of motor | Electronically commutated (EC) |
| With constant pressure control | No |
| Efficiency supply filter according to ISO 16890-1:2016 | 45 % |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 45 % |
| Max. air volume at 150 Pa | 290 m³/h |
| Max. air volume at 50 Pa | 335 m³/h |
| Max. air volume at 250 Pa | 230 m³/h |
| With constant volume flow control | No |
| With bypass | Yes |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Weight | 34 kg |
| Device emplacement | Indoor positioning |
| With thermal overload protection | Yes |
| Max. air volume at 300 Pa | 195 m³/h |
| Type of heating coil | None |
| Power consumption | 0.09 kW |
| Frost protection circuit | No |
| Type of cooling coil | None |
| Suitable for transformer control | No |
| Suitable for electronic control | Yes |
| Connection voltage | 1x 230 V AC |
| Change-over system | No |
| Fan type | Direct |
| With condensate drain | No |
| With rotational speed/frequency control | Yes |
| With support frame | No |
| With roof plate | No |
| Nominal duct diameter, outdoor connection | 160 mm |
| Suitable for low-current control | Yes |
| Thermal efficiency | 75 % |
| With enthalpy exchanger | No |