Item number: 19130111
Pay safe and fast with:
The Orcon HRC-260 OptiAir Eco is a balanced ventilation system with heat recovery designed for houses and apartments. The unit operates on demand: the airflow rate automatically adjusts based on the indoor air quality, ensuring ventilation only occurs when necessary. With a thermal efficiency of 91.7% and an A+ energy label, the system recovers nearly all the heat from the extracted air and transfers it to the fresh supply air. The Eco version is the base model without a preheater, with frost protection managed through imbalance control.
At an airflow capacity of 260 m³/h, the HRC-260 OptiAir Eco consumes a maximum of just 53 W. Thanks to constant volume control and demand-driven operation, the unit runs most of the day at low speed, which reduces both energy consumption and noise levels. The ePM1 70% filter class on the supply side keeps fine dust out, noticeably improving indoor air quality.
The HRC-260 OptiAir Eco is suitable for both new builds and renovations in houses and apartments. The duct connections are 4 x 160 mm, and the unit is supplied with a standard grounded power cable. Ceiling mounting is the default configuration; wall and floor mounting are possible with a separately available mounting kit. Thanks to its low weight of 23 kg, the unit can be lifted and positioned by one person. Maintenance is limited to periodic filter replacement, which can be done without removing the unit from the ceiling. The airflow per setting can be configured for the specific situation in the building via dipswitches on the control board.
| Brand | Orcon |
| Category | All MVHR units |
| GTIN | 8720701078352 |
| Manufacturer's item number | 22020200 |
| Article number | 19130027 |
| Category code | 218 |
| Housing material | Plastic |
| Housing material quality | Expanded polypropylene (EPP) |
| Material heat exchanger | Plastic |
| Suitable for wall mounting | Yes |
| Suitable for ceiling mounting | Yes |
| Suitable for floor mounting | Yes |
| Suitable for mounting in suspended ceiling | Yes |
| Suitable for mounting in an attic | Yes |
| Orientation | Left/right (reversible) |
| Max. air volume at 50 Pa | 260 m³/h |
| Max. air volume at 100 Pa | 260 m³/h |
| Max. air volume at 150 Pa | 260 m³/h |
| Max. air volume at 200 Pa | 260 m³/h |
| Max. air volume at 250 Pa | 260 m³/h |
| Max. air volume at 300 Pa | 260 m³/h |
| Sound power level according to 1254/2014/EU | 45 dB(A) |
| Power consumption at max. air volume at 100 Pa | 65 W |
| Thermal efficiency at 70% air volume at 50 Pa | 91.7 % |
| Type of motor | Electronically commutated (EC) |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Number of phases | 1 |
| Fuse size of the device | 6 A |
| With thermal overload protection | No |
| Electrical connection | Connecting cable with plug with protective contact |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Type of switch | Other |
| With digital display | No |
| With wired control unit | No |
| Suitable for wired control unit | No |
| With wireless remote control | No |
| Suitable for wireless remote control | Yes |
| Supporting protocol for Modbus | Yes |
| Operation by app | No |
| With zone controller | No |
| Suitable for zone controller | Yes |
| With heating element | No |
| With volatile organic compound (VOC) sensor | No |
| Suitable for extra VOC sensor | No |
| With external humidity (RH) sensor | No |
| With internal humidity (RH) sensor | Yes |
| Suitable for (extra) humidity (RH) sensor | Yes |
| With internal carbon dioxide (CO2) sensor | No |
| Suitable for (extra) carbon dioxide (CO2) sensor | Yes |
| Suitable for central heating boiler connection | No |
| With bypass | Yes |
| With constant pressure control | No |
| With constant volume flow control | Yes |
| Type of frost protection | Other |
| Nominal duct diameter (min) | 160 mm |
| Nominal duct diameter (max) | 160 mm |
| Number of outdoor air connections (ODA) according to EN 13141-7 | 1 |
| Number of supply air connections (SUP) according to EN 13141-7 | 1 |
| Number of extract air connections (ETA) according to EN 13141-7 | 1 |
| Number of exhaust air connections (EHA) according to EN 13141-7 | 1 |
| Connections outdoor air (ODA) | Insert end |
| Connections supply air (SUP) | Insert end |
| Connections extract air (ETA) | Insert end |
| Connections exhaust air (EHA) | Insert end |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Efficiency supply filter according to ISO 16890-1:2016 | 70 % |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Height | 830 mm |
| Width | 1080 mm |
| Depth | 324 mm |
| Degree of protection (IP) | IP30 |
| Weight | 23.55 kg |
| Heat recovery by | Cross-counter-flow unit |