In stock
Item number: 19100090
Pay safe and fast with:
Orcon's decentralised heat recovery unit is specially developed for creating an optimal indoor climate. In many offices and other spaces, the CO2 values are often too high. This can be prevented by installing a decentralised heat recovery unit. Each individual room is thus provided with healthy and fresh air and contributes to an optimal indoor climate. Orcon's MVHR units are among the smartest on the market. They have various sensors and an integrated smart controller and display.
The WTU- EC-IE is equipped with insulation material and double housing. This way the noise level is kept to a minimum and creates the possibility for installing the unit directly in a classroom or office space.
To save heat, this balanced ventilation system is equipped with heat recovery. Therefore, the WTU-EC-EI heats the cold air from outside with the warm air from inside. In order to obtain cool air in the summer and to not heat up the room further, the unit is equipped as standard with a bypass. This option ensures that cold, filtered air is brought in from outside during the night. Besides recovering heat, the system also recovers humidity by means of an enthalpy heat exchanger. This keeps the temperature and relative humidity at a comfortable level.
Orcon also offers software via their E-tool:
| Brand | Orcon |
| Category | Heat recovery choice aid |
| GTIN | 8718403862843 |
| Manufacturer's item number | 15104010 |
| Article number | 19220052 |
| Category code | 17 |
| Length | 1657 mm |
| Connection | Flange |
| Width | 1351 mm |
| Height | 472 mm |
| Housing material | Steel, lined |
| Heat recovery by | Cross-counter-flow unit |
| Max. air volume at 100 Pa | 1070 m³/h |
| Max. air volume at 200 Pa | 920 m³/h |
| Electrical connection | Connection cable with plug |
| Type of motor | Electronically commutated (EC) |
| With constant pressure control | No |
| Efficiency supply filter according to ISO 16890-1:2016 | 45 % |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 45 % |
| Max. air volume at 150 Pa | 980 m³/h |
| Max. air volume at 50 Pa | 1160 m³/h |
| Max. air volume at 250 Pa | 840 m³/h |
| With constant volume flow control | No |
| With bypass | Yes |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Weight | 135 kg |
| Device emplacement | Indoor positioning |
| With thermal overload protection | Yes |
| Max. air volume at 300 Pa | 750 m³/h |
| Type of heating coil | None |
| Power consumption | 0.354 W |
| Frost protection circuit | No |
| Type of cooling coil | None |
| Suitable for transformer control | No |
| Suitable for electronic control | Yes |
| Connection voltage | 1x 230 V AC |
| Change-over system | No |
| Fan type | Direct |
| With condensate drain | No |
| With rotational speed/frequency control | Yes |
| With support frame | No |
| With roof plate | No |
| Nominal duct diameter, outdoor connection | 315 mm |
| Suitable for low-current control | Yes |
| Thermal efficiency | 76 % |
| Max. air volume at 400 Pa | 580 m³/h |
| With enthalpy exchanger | No |