- Brand: Maxivent
- Heat exchanger compliant with EN 308 and Eurovent-certified
- Hot-water coil and DX cooling
- Plug & Play Integrated Controller
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 7600 m³/h with Hot Water Coil and DX Cooling Horizontal Left - PHE 7600 H WDJL T 02
The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with hot water coil and DX cooling horizontal left - PHE 7600 H WDJL T 02 is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, medical practices, and medium to large commercial buildings. The air handling unit has a maximum airflow rate of 10,365 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans and is equipped with a hot water coil for heating and a DX cooling coil for cooling the supply air. The unit is designed for floor mounting and can be opened on the left side for maintenance.
Benefits and Features
- Hot Water Coil: Provides efficient and uniform heating of the supply air by utilising hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
- DX Cooling Coil: Cools the supply air directly via direct expansion, ensuring a comfortable indoor climate during warm periods without the need for an additional chilled water system.
- EC Fans: Directly driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-efficient and quiet solution with low electricity consumption.
- Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing airflow streams.
- Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outdoor air, contributing to a healthy and comfortable indoor climate while protecting internal components.
- Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming through the heat exchanger.
- Plug-and-Play Control: The air handling unit is delivered complete with built-in controls for all functions, enabling quick and easy installation and commissioning without extra control technology.
Applications and Usage
The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with hot water coil and DX cooling horizontal left - PHE 7600 H WDJL T 02 are developed for medium to large commercial spaces such as offices, meeting rooms, medical practices, shops, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, hot water coil, and DX cooling, the unit offers comprehensive and energy-efficient climate control even under extreme external temperatures. The integrated control and summer bypass ensure the indoor climate remains comfortable year-round, both in winter and during warm periods.
Customising the WTW Unit
Are you interested in a customised model and want to learn more about the options? Please contact our sales department. They are happy to assist you and help you assemble the ideal unit for your specific requirements.
| Brand | Maxivent |
| Category | Maxivent PHE Counterflow - Side Connection |
| GTIN | 8719544342812 |
| Manufacturer's item number | 78010785 |
| Article number | 78010785 |
Specifications
| Category code | 36 |
| Length | 2840 mm |
| Width | 1710 mm |
| Height | 1760 mm |
| Housing material | Steel |
| Heat recovery by | Counter current unit |
| Electrical connection | Terminals |
| Type of motor | Electronically commutated (EC) |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Degree of protection (IP) | IP41 |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 50 % |
| With bypass | Yes |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Exhaust filter according to ISO 16890-1:2016 | ISO ePM10 |
| Connection voltage | 400 V |
| Surface protection housing | Continuously galvanised |
| External controller required | No |
| Device emplacement | Indoor positioning |
| With thermal overload protection | Yes |
| Type of speed control | Continuously variable |
| Air volume, unloaded | 6206.4 m³/h |
| Type of heating coil | Hot water heat exchanger |
| Type of exhaust fan | Direct |
| Power consumption | 2.69 kW |
| Suitable for frequency control | No |
| Frost protection circuit | Yes |
| Pole-reversible | No |
| Explosion safety | None |
| Type of cooling coil | DX (direct expansion) |
| Suitable for transformer control | No |
| Suitable for electronic control | Yes |
| Type of supply fan | Direct |
| Max. air temperature | 40 °C |
| Change-over system | No |
| With humidifier | No |
| Nominal duct width of suction end | 1200 mm |
| Connection suction side | Rectangular |
| Nominal duct width, delivery side | 1200 mm |
| Number of connections delivery side | 2 |
| Nominal duct height of suction end | 600 mm |
| Connection delivery side | Rectangular |
| Nominal duct height, delivery side | 600 mm |
| Number of connections suction side | 2 |