Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 7600 H WDJL T 02

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 7600 H WDJL T 02
Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 7600 H WDJL T 02
-35%
RRP 52,768.45
34,299.49 -35%
You'll save 18468.96
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • Hot-water coil and DX cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 7600 m³/h with Hot Water Coil and DX Cooling Horizontal Left - PHE 7600 H WDJL T 02

The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with hot water coil and DX cooling horizontal left - PHE 7600 H WDJL T 02 is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, medical practices, and medium to large commercial buildings. The air handling unit has a maximum airflow rate of 10,365 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans and is equipped with a hot water coil for heating and a DX cooling coil for cooling the supply air. The unit is designed for floor mounting and can be opened on the left side for maintenance.

Benefits and Features

  • Hot Water Coil: Provides efficient and uniform heating of the supply air by utilising hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
  • DX Cooling Coil: Cools the supply air directly via direct expansion, ensuring a comfortable indoor climate during warm periods without the need for an additional chilled water system.
  • EC Fans: Directly driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-efficient and quiet solution with low electricity consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing airflow streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outdoor air, contributing to a healthy and comfortable indoor climate while protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit is delivered complete with built-in controls for all functions, enabling quick and easy installation and commissioning without extra control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with hot water coil and DX cooling horizontal left - PHE 7600 H WDJL T 02 are developed for medium to large commercial spaces such as offices, meeting rooms, medical practices, shops, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, hot water coil, and DX cooling, the unit offers comprehensive and energy-efficient climate control even under extreme external temperatures. The integrated control and summer bypass ensure the indoor climate remains comfortable year-round, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to learn more about the options? Please contact our sales department. They are happy to assist you and help you assemble the ideal unit for your specific requirements.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544342812
Manufacturer's item number 78010785
Article number 78010785

Specifications

Category code 36
Length 2840 mm
Width 1710 mm
Height 1760 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 6206.4 m³/h
Type of heating coil Hot water heat exchanger
Type of exhaust fan Direct
Power consumption 2.69 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil DX (direct expansion)
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 1200 mm
Connection suction side Rectangular
Nominal duct width, delivery side 1200 mm
Number of connections delivery side 2
Nominal duct height of suction end 600 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 600 mm
Number of connections suction side 2

Documents

Documents

Reviews