Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with horizontal left-side hot-water coil - PHE 7600 H WOJL T 02

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with horizontal left-side hot-water coil - PHE 7600 H WOJL T 02
Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with horizontal left-side hot-water coil - PHE 7600 H WOJL T 02
Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with horizontal left-side hot-water coil - PHE 7600 H WOJL T 02
Maxivent WTW air handling units with counterflow heat exchanger, 7600 m³/h, with horizontal left-side hot-water coil - PHE 7600 H WOJL T 02
-35%
RRP 45,496.85
29,572.96 -35%
You'll save 15923.89
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • Hot Water Mixer
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 7600 m³/h with Horizontal Left Hot Water Coil - PHE 7600 H WOJL T 02

The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with horizontal left hot water coil - PHE 7600 H WOJL T 02 are high-quality, robust, and advanced balanced ventilation units with heat recovery, specifically designed for offices, practices, and medium to large commercial buildings. The air handling unit has a maximum airflow of 10,510 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans and features a hot water coil that heats the supply air to the desired temperature and helps prevent frost formation in the heat exchanger. The air handling unit is designed for floor mounting and can be opened on the left side for maintenance.

Benefits and Features

  • Hot Water Coil: Provides efficient and even heating of the supply air using hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-saving and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the extract air without mixing air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming it in the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes complete with built-in control for all functions, facilitating quick and easy installation and commissioning without the need for additional control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 7600 m³/h with horizontal left hot water coil - PHE 7600 H WOJL T 02 are designed for medium to large commercial spaces such as offices, meeting rooms, practices, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and the hot water coil, the unit delivers stable and energy-efficient ventilation, even at low outdoor temperatures. The integrated control and summer bypass ensure that the indoor climate remains comfortable throughout the year, both in winter and during warm periods.

Customising the WTW Unit

Interested in a customised model and want to know more about the options? Please contact our sales department. They will be happy to assist you and help you configure the ideal unit for your specific requirements.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544342799
Manufacturer's item number 78010783
Article number 78010783

Specifications

Category code 36
Length 2840 mm
Width 1710 mm
Height 1760 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 6206.4 m³/h
Type of heating coil Hot water heat exchanger
Type of exhaust fan Direct
Power consumption 2.6 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 1200 mm
Connection suction side Rectangular
Nominal duct width, delivery side 1200 mm
Number of connections delivery side 2
Nominal duct height of suction end 600 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 600 mm
Number of connections suction side 2