Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 700 m³/h, Horizontal-Horizontal, Left-Handed - PHE 700 H OOJL

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 700 m³/h, Horizontal-Horizontal, Left-Handed - PHE 700 H OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 700 m³/h, Horizontal-Horizontal, Left-Handed - PHE 700 H OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 700 m³/h, Horizontal-Horizontal, Left-Handed - PHE 700 H OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 700 m³/h, Horizontal-Horizontal, Left-Handed - PHE 700 H OOJL
-35%
RRP 9,544.70
6,204.06 -35%
You'll save 3340.64
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • No heating, no cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 700 m³/h Horizontal Horizontal Left - PHE 700 H OOJL

The Maxivent WTW air handling units with counterflow heat exchanger 700 m³/h horizontal horizontal left - PHE 700 H OOJL is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specially designed for offices, practices, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 890 m³/h and features an EN 308 and Eurovent certified heat exchanger. The unit operates with a counterflow heat exchanger and EC fans, is designed for floor mounting, and can be opened from the left side for maintenance.

Advantages and Features

  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) provide an energy-efficient and quiet solution with low electrical consumption.
  • Counterflow Exchanger: The integrated counterflow heat exchanger is certified according to EN 308 and Eurovent, independently verifying the reliability and quality of the heat recovery.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outdoor air, contributing to a healthy and comfortable indoor climate and protecting the internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming in the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes complete with built-in controls for all functions, allowing for quick and easy installation and commissioning without additional control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 700 m³/h horizontal horizontal left - PHE 700 H OOJL are developed for small to medium-sized commercial spaces such as offices, meeting rooms, practices, shops, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit delivers stable and energy-efficient ventilation. The integrated control and summer bypass ensure a comfortable indoor climate all year round, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and would like to know more about the options? Please contact our sales department. They are happy to assist you and help design the ideal unit for your situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544342393
Manufacturer's item number 78010743
Article number 78010743

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 630 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil None
Type of heating coil None
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 230 V
Power consumption 0.3 kW
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 250 mm
Nominal duct width of suction end 400 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 250 mm
Nominal duct width, delivery side 400 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 776 mm
Width 708 mm
Length 1430 mm

Documents

Documents

Reviews