- Merk: Maxivent
- Warmtewisselaar EN 308 en Eurovent-gecertificeerd
- Warmwaterbatterij en koudwaterbatterij
- Plug & Play geïntegreerde controller
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 5000 m³/h with Hot Water Coil and Chilled Water Coil Horizontal Left - PHE 5000 H WKJL T 01
The Maxivent WTW air handling units with counterflow heat exchanger 5000 m³/h with hot water coil and chilled water coil horizontal left - PHE 5000 H WKJL T 01 is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, practices, and medium to large commercial buildings. The air handling unit has a maximum airflow of 7120 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans, and is equipped with a hot water coil for heating and a chilled water coil for cooling the supply air. The air handling unit is intended for floor mounting and can be opened from the left side for maintenance.
Advantages and Features
- Hot Water Coil: Provides efficient and even heating of the supply air using hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
- Chilled Water Coil: Cools the supply air via chilled water from a cooling system, enabling energy-efficient and precisely controllable cooling of the room air.
- EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-saving and quiet solution with low electricity consumption.
- Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing air streams.
- Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor environment and protecting internal components.
- Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming through the heat exchanger.
- Plug-and-Play Control: The air handling unit comes complete with built-in control for all functions, allowing for quick and easy installation and commissioning without the need for additional control technology.
Applications and Use
The Maxivent WTW air handling units with counterflow heat exchanger 5000 m³/h with hot water coil and chilled water coil horizontal left - PHE 5000 H WKJL T 01 have been developed for medium to large commercial spaces such as offices, meeting rooms, practices, retail, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, hot water coil, and chilled water coil, the unit provides comprehensive and precisely controllable climate control throughout the year. The integrated control and summer bypass ensure the indoor climate remains comfortable year-round, both in winter and during warm periods.
Customising the WTW Unit
Are you interested in a customised model and want to know more about the options? Please contact our sales department. They are happy to assist you and help you design the ideal unit for your situation.
| Brand | Maxivent |
| Category | Maxivent PHE Counterflow - Side Connection |
| GTIN | 8719544341785 |
| Manufacturer's item number | 78010682 |
| Article number | 78010682 |
Specifications
| Category code | 36 |
| Device emplacement | Indoor positioning |
| Housing material | Steel |
| Surface protection housing | Continuously galvanised |
| Air volume, unloaded | 3913.2 m³/h |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Heat recovery by | Counter current unit |
| With bypass | Yes |
| Type of cooling coil | Water/glycol |
| Type of heating coil | Hot water heat exchanger |
| Change-over system | No |
| With humidifier | No |
| Type of supply fan | Direct |
| Exhaust filter according to ISO 16890-1:2016 | ISO ePM10 |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 50 % |
| Type of exhaust fan | Direct |
| Connection voltage | 400 V |
| Power consumption | 1.91 kW |
| With thermal overload protection | Yes |
| Electrical connection | Terminals |
| Suitable for electronic control | Yes |
| Suitable for frequency control | No |
| Suitable for transformer control | No |
| Pole-reversible | No |
| External controller required | No |
| Frost protection circuit | Yes |
| Type of motor | Electronically commutated (EC) |
| Type of speed control | Continuously variable |
| Number of connections suction side | 2 |
| Connection suction side | Rectangular |
| Nominal duct height of suction end | 500 mm |
| Nominal duct width of suction end | 1000 mm |
| Connection delivery side | Rectangular |
| Number of connections delivery side | 2 |
| Nominal duct height, delivery side | 500 mm |
| Nominal duct width, delivery side | 1000 mm |
| Degree of protection (IP) | IP41 |
| Explosion safety | None |
| Max. air temperature | 40 °C |
| Height | 1305 mm |
| Width | 1380 mm |
| Length | 2976 mm |