Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, with DX Coil, Horizontal Right-Hand Configuration - PHE 5000 H ODJR T 01

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, with DX Coil, Horizontal Right-Hand Configuration - PHE 5000 H ODJR T 01
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, with DX Coil, Horizontal Right-Hand Configuration - PHE 5000 H ODJR T 01
-35%
RRP 35,160.97
22,854.64 -35%
You'll save 12306.33
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Merk: Maxivent
  • Warmtewisselaar EN 308 en Eurovent-gecertificeerd
  • DX batterij
  • Plug & Play geïntegreerde controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 5000 m3/h with DX Coil Horizontal Right - PHE 5000 H ODJR T 01

The Maxivent WTW air handling units with counterflow heat exchanger 5000 m3/h with DX coil horizontal right - PHE 5000 H ODJR T 01 is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, clinics, and medium to large commercial buildings. The air handling unit has a maximum airflow of 7300 m³/h and a thermal efficiency of 82%. It operates with a counterflow heat exchanger and EC fans and features an integrated DX coil that can both heat and cool the supply air. The unit is designed for floor mounting and can be opened on the right side for maintenance.

Benefits and Features

  • DX Coil (heating and cooling): Direct expansion unit providing both heating and cooling of the supply air via a single integrated system, simplifying installation and offering high comfort during fluctuating outdoor temperatures.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) deliver an energy-efficient and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes complete with built-in controls for all functions, enabling quick and easy installation and commissioning without additional control equipment.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 5000 m3/h with DX coil horizontal right - PHE 5000 H ODJR T 01 are developed for medium to large commercial spaces such as offices, meeting rooms, clinics, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and the integrated DX coil, the unit delivers both heating and cooling in a compact and energy-efficient manner. The integrated control and summer bypass ensure a comfortable indoor climate throughout the year, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to know more about the options? Please contact our sales department. They are happy to discuss your needs and assist you in configuring the ideal unit for your situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544341747
Manufacturer's item number 78010678
Article number 78010678

Specifications

Category code 36
Length 2976 mm
Width 1380 mm
Height 1305 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 3902.4 m³/h
Type of heating coil DX (direct expansion)
Type of exhaust fan Direct
Power consumption 1.85 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil DX (direct expansion)
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 1000 mm
Connection suction side Rectangular
Nominal duct width, delivery side 1000 mm
Number of connections delivery side 2
Nominal duct height of suction end 500 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 500 mm
Number of connections suction side 2