Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, Horizontal-Horizontal, Left-Handed - PHE 5000 H OOJL T 01

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, Horizontal-Horizontal, Left-Handed - PHE 5000 H OOJL T 01
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, Horizontal-Horizontal, Left-Handed - PHE 5000 H OOJL T 01
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, Horizontal-Horizontal, Left-Handed - PHE 5000 H OOJL T 01
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 5000 m³/h, Horizontal-Horizontal, Left-Handed - PHE 5000 H OOJL T 01
-35%
RRP 28,633.04
18,611.48 -35%
You'll save 10021.56
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • No heating, no cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 5000 m3/h Horizontal Left - PHE 5000 H OOJL T 01

The Maxivent WTW air handling units with counterflow heat exchanger 5000 m3/h horizontal left - PHE 5000 H OOJL T 01 are high-quality, robust, and advanced balanced ventilation units with heat recovery, specially designed for offices, practices, and medium to large commercial buildings. The air handling unit offers a maximum air capacity of 7450 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans, is designed for floor mounting, and can be opened on the left side for maintenance.

Benefits and Features

  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) provide an energy-efficient and quiet solution with low electricity consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from exhaust air without mixing the air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor climate and protecting the internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit is delivered complete with built-in controls for all functions, allowing quick and straightforward installation and commissioning without extra control equipment.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 5000 m3/h horizontal left - PHE 5000 H OOJL T 01 are developed for medium to large commercial spaces such as offices, meeting rooms, practices, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit provides stable and energy-efficient ventilation. The integrated control and summer bypass ensure a comfortable indoor climate throughout the year, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to learn more about the options? Please contact our sales department. They will gladly assist you and help design the ideal unit for your specific requirements.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544341754
Manufacturer's item number 78010679
Article number 78010679

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 3938.4 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil None
Type of heating coil None
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 400 V
Power consumption 1.86 kW
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 500 mm
Nominal duct width of suction end 1000 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 500 mm
Nominal duct width, delivery side 1000 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 1305 mm
Width 1380 mm
Length 2320 mm

Documents

Documents

Reviews