Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 4200 H WDJL T 01

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 4200 H WDJL T 01
Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, with hot-water coil and DX cooling, horizontal left-hand configuration - PHE 4200 H WDJL T 01
-35%
RRP 36,217.67
23,541.48 -35%
You'll save 12676.19
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • Hot-water coil and DX cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 4200 m³/h with Hot Water Coil and DX Cooling Horizontal Left - PHE 4200 H WDJL T 01

The Maxivent WTW air handling units with counterflow heat exchanger 4200 m³/h with hot water coil and DX cooling horizontal left - PHE 4200 H WDJL T 01 is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, clinics, and medium to large commercial buildings. The air handling unit features a maximum airflow of 5180 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans, equipped with a hot water coil for heating and a DX cooling coil for supply air cooling. The air handling unit is designed for floor mounting and can be opened on the left side for maintenance.

Benefits and Features

  • Hot Water Coil: Ensures efficient and uniform heating of the supply air by utilising hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
  • DX Cooling Coil: Cools the supply air directly via direct expansion, maintaining indoor comfort during warm periods without the need for additional chilled water systems.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronically commutated (EC) motors provide an energy-saving and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing air streams.
  • Panel Filter F7/M5: Provides a high level of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor environment and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outside air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes complete with built-in control for all functions, allowing quick and easy installation and commissioning without additional control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 4200 m³/h with hot water coil and DX cooling horizontal left - PHE 4200 H WDJL T 01 have been developed for medium to large commercial spaces such as offices, meeting rooms, clinics, retail, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, hot water coil, and DX cooling, the unit delivers comprehensive and energy-efficient climate control, even under extreme outdoor temperatures. The integrated control and summer bypass ensure a comfortable indoor climate throughout the year, both in winter and during warm periods.

Customising the WTW Unit

If you are interested in a customised model and want to learn more about the options, please contact our sales department. They will be happy to assist you in designing the ideal unit for your specific situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544341624
Manufacturer's item number 78010666
Article number 78010666

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 3805.2 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil DX (direct expansion)
Type of heating coil Hot water heat exchanger
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 400 V
Power consumption 1.9 kW
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 500 mm
Nominal duct width of suction end 1000 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 500 mm
Nominal duct width, delivery side 1000 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 1305 mm
Width 1380 mm
Length 2976 mm

Documents