Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, horizontal-horizontal, right-side configuration - PHE 4200 H OOJR T 01

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, horizontal-horizontal, right-side configuration - PHE 4200 H OOJR T 01
Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, horizontal-horizontal, right-side configuration - PHE 4200 H OOJR T 01
Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, horizontal-horizontal, right-side configuration - PHE 4200 H OOJR T 01
Maxivent WTW air handling units with counterflow heat exchanger, 4200 m³/h, horizontal-horizontal, right-side configuration - PHE 4200 H OOJR T 01
-35%
RRP 27,164.05
17,656.63 -35%
You'll save 9507.42
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • No heating, no cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 4200 m³/h Horizontal Horizontal Right - PHE 4200 H OOJR T 01

The Maxivent WTW air handling units with counterflow heat exchanger 4200 m³/h horizontal horizontal right - PHE 4200 H OOJR T 01 is a high-quality, robust and advanced balanced ventilation unit with heat recovery, specifically designed for offices, medical practices, and medium to large commercial buildings. The air handling unit has a maximum airflow of 5560 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans, is designed for floor mounting, and can be opened on the right side for maintenance.

Advantages and Features

  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) provide an energy-efficient and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing the airflow streams.
  • Panel Filter F7/M5: Ensures a high degree of filtration of dust particles and pollutants from the outdoor air, contributing to a healthy and comfortable indoor climate as well as protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming through the heat exchanger.
  • Plug-and-Play Controls: The air handling unit is delivered complete with built-in control for all functions, allowing quick and easy installation and commissioning without additional control systems.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 4200 m³/h horizontal horizontal right - PHE 4200 H OOJR T 01 are developed for medium to large commercial spaces such as offices, meeting rooms, medical practices, retail environments, and educational or healthcare facilities. Thanks to the combination of heat recovery and EC fans, the unit provides stable and energy-efficient ventilation. The integrated control and summer bypass ensure the indoor climate remains comfortable year-round, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to learn more about the options? Please contact our sales department. They will be happy to assist you and help you configure the ideal unit tailored to your specific situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544341501
Manufacturer's item number 78010654
Article number 78010654

Specifications

Category code 36
Length 2320 mm
Width 1380 mm
Height 1305 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 3841.2 m³/h
Type of heating coil None
Type of exhaust fan Direct
Power consumption 1.82 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 1000 mm
Connection suction side Rectangular
Nominal duct width, delivery side 1000 mm
Number of connections delivery side 2
Nominal duct height of suction end 500 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 500 mm
Number of connections suction side 2

Documents