Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 3500 m³/h, with electric heater on the left - PHE 3500 F EOJL

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 3500 m³/h, with electric heater on the left - PHE 3500 F EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 3500 m³/h, with electric heater on the left - PHE 3500 F EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 3500 m³/h, with electric heater on the left - PHE 3500 F EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 3500 m³/h, with electric heater on the left - PHE 3500 F EOJL
-35%
RRP 26,622.22
17,304.44 -35%
You'll save 9317.78
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Merk: Maxivent
  • Warmtewisselaar EN 308 en Eurovent-gecertificeerd
  • Elektrische verwarming
  • Plug & Play geïntegreerde controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 3500 m³/h with Left Electric Heater - PHE 3500 F EOJL

The Maxivent WTW air handling units with counterflow heat exchanger 3500 m³/h with left electric heater - PHE 3500 F EOJL is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specially designed for offices, clinics, and small to medium-sized commercial buildings. The AHU has a maximum airflow of 4450 m³/h and a thermal efficiency of 85%. The unit operates with a counterflow heat exchanger and EC fans and is equipped with an electric heater that ensures a stable and constant supply air temperature and prevents frost formation in the heat exchanger. The air handling unit is designed for ceiling installation and can be opened from the bottom for maintenance.

Benefits and Features

  • Electric Heater: Integrated electric reheating prevents cold drafts and ensures a comfortable and stable supply air temperature, without the need for a hot water connection.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) provide an energy-efficient and quiet solution with low electricity consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 85% of the thermal energy from the exhaust air, without mixing air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and pollutants from outdoor air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming it in the heat exchanger.
  • Plug-and-Play Control: The air handling unit is delivered complete with built-in control for all functions, making installation and commissioning quick and straightforward without extra control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 3500 m³/h with left electric heater - PHE 3500 F EOJL are developed for small to medium-sized commercial spaces such as offices, meeting rooms, clinics, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and electric heating, the unit provides stable and energy-efficient ventilation, even at low outdoor temperatures. The integrated control and summer bypass ensure the indoor climate remains comfortable throughout the year, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to learn more about the options? Please contact our sales department. They will be happy to assist you in designing the ideal unit for your specific situation.

Brand Maxivent
Category Maxivent PHE Ceiling Units
GTIN 8719544341969
Manufacturer's item number 78010700
Article number 78010700

Specifications

Category code 36
Length 2400 mm
Width 1820 mm
Height 660 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 2930.4 m³/h
Type of heating coil Electrical heating element
Type of exhaust fan Direct
Power consumption 1.45 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 700 mm
Connection suction side Rectangular
Nominal duct width, delivery side 700 mm
Number of connections delivery side 2
Nominal duct height of suction end 400 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 400 mm
Number of connections suction side 2