Maxivent WTW air handling units with counterflow heat exchanger, 2800 m³/h, with vertical left-side hot-water coil - PHE 2800 V WOJL

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 2800 m³/h, with vertical left-side hot-water coil  - PHE 2800 V WOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2800 m³/h, with vertical left-side hot-water coil  - PHE 2800 V WOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2800 m³/h, with vertical left-side hot-water coil  - PHE 2800 V WOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2800 m³/h, with vertical left-side hot-water coil  - PHE 2800 V WOJL
-35%
RRP 22,600.48
14,690.32 -35%
You'll save 7910.16
Delivery time: 12 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • Hot Water Mixer
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 2800 m³/h with Hot Water Coil Vertical Left - PHE 2800 V WOJL

The Maxivent WTW air handling units with counterflow heat exchanger 2800 m³/h with hot water coil vertical left - PHE 2800 V WOJL are high-quality, robust, and advanced balanced ventilation units with heat recovery, specifically designed for offices, medical practices, and large commercial buildings. The air handling unit has a maximum airflow of 3575 m³/h and a thermal efficiency of 83%. The unit operates with a counterflow heat exchanger and EC fans and features a hot water coil that heats the supply air to the desired temperature while preventing frost formation in the heat exchanger. The AHU is designed for floor mounting and can be opened on the left side for maintenance.

Advantages and Features

  • Hot Water Coil: Ensures efficient and even heating of the supply air by using hot water from a central heating system or heat pump, resulting in a comfortable indoor climate and energy-efficient heat transfer.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation offer an energy-saving and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 83% of the thermal energy from the extract air without mixing air streams.
  • Panel Filter F7/M5: Provides a high level of filtration of dust particles and contaminants from the outdoor air, contributing to a healthy and comfortable indoor environment and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming in the heat exchanger.
  • Plug-and-Play Control: The AHU is supplied complete with built-in control for all functions, making installation and commissioning quick and straightforward without additional control technology.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 2800 m³/h with hot water coil vertical left - PHE 2800 V WOJL are designed for large commercial spaces such as offices, meeting rooms, medical practices, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and the hot water coil, the unit delivers stable and energy-efficient ventilation, even at low outdoor temperatures. The integrated controls and summer bypass ensure a comfortable indoor climate throughout the year, both in winter and during warm periods.

Brand Maxivent
Category Maxivent PHE counterflow - top connection
GTIN 8719544333162
Manufacturer's item number Maxivent PHE 2800 V WOJL
Article number 78010541

Specifications

Category code 36
Length 2194 mm
Width 869 mm
Height 1706 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 400 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 3575 m³/h
Type of heating coil Hot water heat exchanger
Type of exhaust fan Direct
Power consumption 1.123 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 600 mm
Connection suction side Rectangular
Nominal duct width, delivery side 600 mm
Number of connections delivery side 2
Nominal duct height of suction end 400 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 400 mm
Number of connections suction side 2

Reviews