Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 2500 m³/h, Horizontal Left - PHE 2500 F OOJL

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 2500 m³/h, Horizontal Left - PHE 2500 F OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 2500 m³/h, Horizontal Left - PHE 2500 F OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 2500 m³/h, Horizontal Left - PHE 2500 F OOJL
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 2500 m³/h, Horizontal Left - PHE 2500 F OOJL
-35%
RRP 18,203.27
11,832.13 -35%
You'll save 6371.14
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • No heating, no cooling
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 2500 m3/h Horizontal Left - PHE 2500 F OOJL

The Maxivent WTW air handling units with counterflow heat exchanger 2500 m3/h horizontal left - PHE 2500 F OOJL is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specially designed for offices, practices, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 3030 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans, is designed for ceiling installation, and can be opened from the bottom for maintenance.

Benefits and Features

  • EC fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-efficient and quiet solution with low power consumption.
  • Counterflow heat exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing the air streams.
  • Panel filter F7/M5: Ensures a high level of filtration of dust particles and pollutants from outside air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic summer bypass: Enables summer and night cooling by supplying cool outside air directly without warming it in the heat exchanger.
  • Plug-and-Play control: The air handling unit is delivered complete with built-in controls for all functions, making installation and commissioning quick and straightforward without additional control technology.

Applications and Use

The Maxivent WTW air handling units with counterflow heat exchanger 2500 m3/h horizontal left - PHE 2500 F OOJL are designed for small to medium-sized commercial spaces such as offices, meeting rooms, practices, shops, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit provides stable and energy-efficient ventilation. The integrated control and summer bypass ensure the indoor climate remains comfortable throughout the year, both in winter and during warm periods.

Customising the WTW Unit

Are you interested in a customised model and want to know more about the possibilities? Please contact our sales department. They will be happy to discuss your requirements and assist you in configuring the ideal unit for your situation.

Brand Maxivent
Category Maxivent PHE Ceiling Units
GTIN 8719544341198
Manufacturer's item number 78010623
Article number 78010623

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 1562.4 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil None
Type of heating coil None
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 230 V
Power consumption 1.21 kW
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 300 mm
Nominal duct width of suction end 700 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 300 mm
Nominal duct width, delivery side 700 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 520 mm
Width 1900 mm
Length 2000 mm