Free shipping from 100,-
100 day return period
Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with electric heater, vertical, left-hand configuration - PHE 2000 V EOJL

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with electric heater, vertical, left-hand configuration - PHE 2000 V EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with electric heater, vertical, left-hand configuration - PHE 2000 V EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with electric heater, vertical, left-hand configuration - PHE 2000 V EOJL
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with electric heater, vertical, left-hand configuration - PHE 2000 V EOJL
-35%
RRP 17,373.29
11,292.64 -35%
You'll save 6080.65
Delivery time: 12 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • Electric heating
  • Plug and play integrated control

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 2000 m³/h with Electric Heater Vertical Left - PHE 2000 V EOJL

The Maxivent WTW air handling units with counterflow heat exchanger 2000 m³/h with electric heater vertical left - PHE 2000 V EOJL are high-quality, robust, and advanced balanced ventilation units with heat recovery, specially designed for offices, clinics, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow rate of 2745 m³/h and a thermal efficiency of 80%. The unit operates with a counterflow heat exchanger and EC fans, and is equipped with an electric heater that ensures a stable and consistent supply air temperature while preventing frost formation in the heat exchanger. The air handling unit is designed for floor mounting and can be opened on the left side for maintenance.

Benefits and Features

  • Electric Heater: Integrated electric reheating prevents cold drafts and ensures a comfortable and stable supply air temperature without the need for a hot water connection.
  • EC Fans: Direct-driven EC plug fans with high-efficiency Electronically Commutated (EC) motors provide an energy-efficient and quiet solution with low electrical consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 80% of the thermal energy from the exhaust air without mixing air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and pollutants from the outdoor air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without heating through the heat exchanger.
  • Plug-and-Play Control: The unit comes fully equipped with built-in controls for all functions, allowing quick and easy installation and commissioning without additional control equipment.

Applications and Usage

The Maxivent WTW air handling units with counterflow heat exchanger 2000 m³/h with electric heater vertical left - PHE 2000 V EOJL are designed for small to medium-sized commercial spaces such as offices, meeting rooms, clinics, retail shops, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and electric heating, the unit provides stable and energy-efficient ventilation even at low outdoor temperatures. The integrated control system and summer bypass ensure a comfortable indoor climate throughout the year, both in winter and during warm periods.

Brand Maxivent
Category Maxivent PHE counterflow - top connection
GTIN 8719544333063
Manufacturer's item number Maxivent PHE 2000 V EOJL
Article number 78010531

Specifications

Category code 36
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 2745 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil None
Type of heating coil Electrical heating element
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 400 V
Power consumption 0.726 W
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 600 mm
Nominal duct width of suction end 300 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 600 mm
Nominal duct width, delivery side 300 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 1350 mm
Width 869 mm
Length 1770 mm
Device emplacement Indoor positioning

Reviews