Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with DX coil, horizontal, right-side mounting - PHE 2000 H ODJR

Brand: Maxivent


Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with DX coil, horizontal, right-side mounting - PHE 2000 H ODJR
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with DX coil, horizontal, right-side mounting - PHE 2000 H ODJR
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with DX coil, horizontal, right-side mounting - PHE 2000 H ODJR
Maxivent WTW air handling units with counterflow heat exchanger, 2000 m³/h, with DX coil, horizontal, right-side mounting - PHE 2000 H ODJR
-35%
RRP 16,420.18
10,673.11 -35%
You'll save 5747.07
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • DX battery
  • Plug & Play Integrated Controller

Maxivent WTW Air Handling Units with Counterflow Exchanger 2000 m³/h with Horizontal Right DX Coil - PHE 2000 H ODJR

The Maxivent WTW air handling units with counterflow exchanger 2000 m³/h with horizontal right DX coil - PHE 2000 H ODJR is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, clinics, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 2670 m³/h and a thermal efficiency of 83%. The unit operates with a counterflow heat exchanger and EC fans and features an integrated DX coil capable of both heating and cooling the supply air. The air handling unit is designed for floor mounting and can be opened on the right side for maintenance.

Benefits and Features

  • DX Coil (heating and cooling): Direct expansion unit that provides both heating and cooling of the supply air through one integrated system, simplifying installation and providing high comfort during varying outdoor temperatures.
  • EC Fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) offer an energy-efficient and quiet solution with low electricity consumption.
  • Counterflow Exchanger: The integrated, efficient counterflow heat exchanger recovers 83% of the thermal energy from the exhaust air, without mixing air streams.
  • Panel Filter F7/M5: Ensures a high degree of filtration of dust particles and contaminants from outside air, contributing to a healthy and comfortable indoor climate and protecting internal components.
  • Automatic Summer Bypass: Allows for summer and night cooling by supplying cool outside air directly without warming it in the heat exchanger.
  • Plug-and-Play Control: The air handling unit is delivered complete with built-in controls for all functions, enabling quick and easy installation and commissioning without additional control technology.

Applications and Use

The Maxivent WTW air handling units with counterflow exchanger 2000 m³/h with horizontal right DX coil - PHE 2000 H ODJR were developed for small to medium-sized commercial spaces such as offices, meeting rooms, clinics, shops, and educational or healthcare environments. Thanks to the combination of heat recovery, EC fans, and the integrated DX coil, the unit provides both heating and cooling in a compact and energy-efficient manner. The integrated control and summer bypass ensure that the indoor climate remains comfortable throughout the year, both in winter and during hot periods.

Customising the WTW Unit

Are you interested in a customised model and want to learn more about the available options? Please contact our sales department. They are happy to advise you and assist you in assembling the ideal unit for your situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544341426
Manufacturer's item number 78010646
Article number 78010646

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 2250 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil DX (direct expansion)
Type of heating coil DX (direct expansion)
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 230 V
Power consumption 1.34 kW
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 350 mm
Nominal duct width of suction end 600 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 350 mm
Nominal duct width, delivery side 600 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 940 mm
Width 869 mm
Length 2000 mm