Item number: 65102804
Pay safe and fast with:
The Maxivent WTW air handling units with counterflow heat exchanger 1300 m3/h vertical left - PHE 1300 V OOJL are high-quality, robust, and advanced balanced ventilation systems with heat recovery, specifically designed for offices, medical practices, and small to medium-sized commercial buildings. The air handling unit offers a maximum airflow of 1680 m³/h and features an EN 308 and Eurovent certified heat exchanger. The unit operates with a counterflow heat exchanger and EC fans, is designed for floor mounting, and can be opened on the left side for maintenance.
The Maxivent WTW air handling units with counterflow heat exchanger 1300 m3/h vertical left - PHE 1300 V OOJL are developed for small to medium-sized commercial spaces such as offices, meeting rooms, medical practices, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit provides stable and energy-efficient ventilation, even at low outside temperatures. The integrated control and summer bypass ensure the indoor climate remains comfortable year-round, both in winter and during warm periods.
| Brand | Maxivent |
| Category | Maxivent PHE counterflow - top connection |
| GTIN | 8719544333025 |
| Manufacturer's item number | Maxivent PHE 1300 V OOJL |
| Article number | 78010527 |
| Category code | 36 |
| Housing material | Steel |
| Surface protection housing | Continuously galvanised |
| Air volume, unloaded | 1680 m³/h |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Heat recovery by | Counter current unit |
| With bypass | Yes |
| Type of cooling coil | None |
| Type of heating coil | None |
| Change-over system | No |
| With humidifier | No |
| Type of supply fan | Direct |
| Exhaust filter according to ISO 16890-1:2016 | ISO ePM10 |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 50 % |
| Type of exhaust fan | Direct |
| Connection voltage | 230 V |
| Power consumption | 0.278 kW |
| With thermal overload protection | Yes |
| Electrical connection | Connection cable with plug |
| Suitable for electronic control | Yes |
| Suitable for frequency control | No |
| Suitable for transformer control | No |
| Pole-reversible | No |
| External controller required | No |
| Frost protection circuit | Yes |
| Type of motor | Electronically commutated (EC) |
| Type of speed control | Continuously variable |
| Number of connections suction side | 2 |
| Connection suction side | Rectangular |
| Nominal duct height of suction end | 500 mm |
| Nominal duct width of suction end | 250 mm |
| Connection delivery side | Rectangular |
| Number of connections delivery side | 2 |
| Nominal duct height, delivery side | 500 mm |
| Nominal duct width, delivery side | 250 mm |
| Degree of protection (IP) | IP41 |
| Explosion safety | None |
| Max. air temperature | 40 °C |
| Height | 1387 mm |
| Width | 809 mm |
| Length | 1430 mm |
| Device emplacement | Indoor positioning |