Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
-35%
RRP 12,572.29
8,171.99 -35%
You'll save 4400.30
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Merk: Maxivent
  • Warmtewisselaar EN 308 en Eurovent-gecertificeerd
  • Zonder verwarming, zonder koeling
  • Plug & Play geïntegreerde controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 1300 m³/h Horizontal Right - PHE 1300 F OOJR

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m³/h horizontal right - PHE 1300 F OOJR are high-quality, robust, and advanced balanced ventilation units with heat recovery, specifically designed for offices, medical practices, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 1500 m³/h and a thermal efficiency of 84%. The unit operates with a counterflow heat exchanger and EC fans, is designed for ceiling mounting, and features a bottom-opening panel for maintenance access.

Benefits and Features

  • EC Fans: Direct-driven EC plug fans with high-efficiency electronically commutated (EC) motors provide an energy-efficient and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 84% of the thermal energy from the exhaust air without mixing the air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and pollutants from the outside air, contributing to a healthy and comfortable indoor climate while protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes fully equipped with built-in controls for all functions, allowing rapid and straightforward installation and commissioning without the need for additional control systems.

Applications and Use

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m³/h horizontal right - PHE 1300 F OOJR are developed for small to medium-sized commercial spaces such as offices, meeting rooms, medical practices, retail outlets, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit delivers stable and energy-efficient ventilation. The integrated controls and summer bypass ensure a comfortable indoor climate all year round, both in winter and during warmer periods.

Customising the WTW Unit

Are you interested in a customised model and want to know more about the options? Please contact our sales department. They will be happy to assist you in designing the ideal unit tailored to your specific needs.

Brand Maxivent
Category Maxivent PHE Ceiling Units
GTIN 8719544341235
Manufacturer's item number 78010627
Article number 78010627

Specifications

Category code 36
Device emplacement Indoor positioning
Housing material Steel
Surface protection housing Continuously galvanised
Air volume, unloaded 622.8 m³/h
Supply filter according to ISO 16890-1:2016 ISO ePM1
Efficiency supply filter according to ISO 16890-1:2016 55 %
Heat recovery by Counter current unit
With bypass Yes
Type of cooling coil None
Type of heating coil None
Change-over system No
With humidifier No
Type of supply fan Direct
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
Type of exhaust fan Direct
Connection voltage 230 V
Power consumption 0.31 W
With thermal overload protection Yes
Electrical connection Terminals
Suitable for electronic control Yes
Suitable for frequency control No
Suitable for transformer control No
Pole-reversible No
External controller required No
Frost protection circuit Yes
Type of motor Electronically commutated (EC)
Type of speed control Continuously variable
Number of connections suction side 2
Connection suction side Rectangular
Nominal duct height of suction end 300 mm
Nominal duct width of suction end 500 mm
Connection delivery side Rectangular
Number of connections delivery side 2
Nominal duct height, delivery side 300 mm
Nominal duct width, delivery side 500 mm
Degree of protection (IP) IP41
Explosion safety None
Max. air temperature 40 °C
Height 435 mm
Width 1460 mm
Length 1800 mm