Free shipping from 100,-
100 day return period
Price Incl Vat

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal Right - PHE 1300 F OOJR
-35%
RRP 12,572.29
8,171.99 -35%
You'll save 4400.30
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Merk: Maxivent
  • Warmtewisselaar EN 308 en Eurovent-gecertificeerd
  • Zonder verwarming, zonder koeling
  • Plug & Play geïntegreerde controller

Maxivent WTW Air Handling Units with Counterflow Heat Exchanger 1300 m³/h Horizontal Right - PHE 1300 F OOJR

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m³/h horizontal right - PHE 1300 F OOJR are high-quality, robust, and advanced balanced ventilation units with heat recovery, specifically designed for offices, medical practices, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 1500 m³/h and a thermal efficiency of 84%. The unit operates with a counterflow heat exchanger and EC fans, is designed for ceiling mounting, and features a bottom-opening panel for maintenance access.

Benefits and Features

  • EC Fans: Direct-driven EC plug fans with high-efficiency electronically commutated (EC) motors provide an energy-efficient and quiet solution with low power consumption.
  • Counterflow Heat Exchanger: The integrated, efficient counterflow heat exchanger recovers 84% of the thermal energy from the exhaust air without mixing the air streams.
  • Panel Filter F7/M5: Ensures a high level of filtration of dust particles and pollutants from the outside air, contributing to a healthy and comfortable indoor climate while protecting internal components.
  • Automatic Summer Bypass: Enables summer and night cooling by supplying cool outdoor air directly without warming through the heat exchanger.
  • Plug-and-Play Control: The air handling unit comes fully equipped with built-in controls for all functions, allowing rapid and straightforward installation and commissioning without the need for additional control systems.

Applications and Use

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m³/h horizontal right - PHE 1300 F OOJR are developed for small to medium-sized commercial spaces such as offices, meeting rooms, medical practices, retail outlets, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit delivers stable and energy-efficient ventilation. The integrated controls and summer bypass ensure a comfortable indoor climate all year round, both in winter and during warmer periods.

Customising the WTW Unit

Are you interested in a customised model and want to know more about the options? Please contact our sales department. They will be happy to assist you in designing the ideal unit tailored to your specific needs.

Brand Maxivent
Category Maxivent PHE Ceiling Units
GTIN 8719544341235
Manufacturer's item number 78010627
Article number 78010627

Specifications

Category code 36
Length 1800 mm
Width 1460 mm
Height 435 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 230 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 622.8 m³/h
Type of heating coil None
Type of exhaust fan Direct
Power consumption 0.31 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 500 mm
Connection suction side Rectangular
Nominal duct width, delivery side 500 mm
Number of connections delivery side 2
Nominal duct height of suction end 300 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 300 mm
Number of connections suction side 2