Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal-Horizontal, Right-Handed - PHE 1300 H OOJR

Brand: Maxivent


Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal-Horizontal, Right-Handed - PHE 1300 H OOJR
Maxivent WTW Air Handling Units with Counterflow Heat Exchanger, 1300 m³/h, Horizontal-Horizontal, Right-Handed - PHE 1300 H OOJR
-35%
RRP 12,293.82
7,990.99 -35%
You'll save 4302.83
Delivery time: 6 weeks
  • The largest collection in the United Kingdom
  • 100 day return period
  • Customer review 9/10
  • Safe shopping with Trustedshops

Pay safe and fast with:

  • Creditcard
  • PayPal
  • Apple Pay

Good points

  • Brand: Maxivent
  • Heat exchanger compliant with EN 308 and Eurovent-certified
  • No heating, no cooling
  • Plug & Play Integrated Controller

Maxivent WTW air handling units with counterflow heat exchanger 1300 m3/h horizontal horizontal right - PHE 1300 H OOJR

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m3/h horizontal horizontal right - PHE 1300 H OOJR is a high-quality, robust, and advanced balanced ventilation unit with heat recovery, specifically designed for offices, medical practices, and small to medium-sized commercial buildings. The air handling unit has a maximum airflow of 1655 m³/h and a thermal efficiency of 82%. The unit operates with a counterflow heat exchanger and EC fans without heating or cooling elements. The air handling unit is designed for floor mounting with horizontal duct connections and can be opened from the side for maintenance.

Advantages and features

  • Counterflow heat exchanger: The integrated, efficient counterflow heat exchanger recovers 82% of the thermal energy from the exhaust air without mixing the air streams.
  • EC fans: Direct-driven EC plug fans with high-efficiency electronic commutation (EC) provide an energy-efficient and quiet solution with low electrical consumption.
  • Panel filter F7/M5: Ensures a high level of filtration of dust particles and contaminants from the outside air, contributing to a healthy and comfortable indoor climate and protecting the internal components.
  • Automatic summer bypass: Enables summer and night cooling by supplying cool outside air directly without warming in the heat exchanger.
  • Plug-and-Play control: The air handling unit is delivered complete with built-in control for all functions, allowing fast and easy installation and commissioning without additional control technology.

Applications and use

The Maxivent WTW air handling units with counterflow heat exchanger 1300 m3/h horizontal horizontal right - PHE 1300 H OOJR is developed for small to medium-sized commercial spaces such as offices, meeting rooms, medical practices, retail stores, and educational or healthcare environments. Thanks to the combination of heat recovery and EC fans, the unit provides stable and energy-efficient ventilation year-round. The integrated control and summer bypass ensure that the indoor climate remains comfortable throughout the year, both in winter and during warm periods.

Customising the WTW unit

Are you interested in a customised model and want to learn more about the possibilities? Please contact our sales department. They are happy to discuss your requirements and assist you in configuring the ideal unit for your situation.

Brand Maxivent
Category Maxivent PHE Counterflow - Side Connection
GTIN 8719544342072
Manufacturer's item number 78010711
Article number 78010711

Specifications

Category code 36
Length 809 mm
Width 1750 mm
Height 940 mm
Housing material Steel
Heat recovery by Counter current unit
Electrical connection Terminals
Type of motor Electronically commutated (EC)
Efficiency supply filter according to ISO 16890-1:2016 55 %
Degree of protection (IP) IP41
Efficiency exhaust filter according to ISO 16890-1:2016 50 %
With bypass Yes
Supply filter according to ISO 16890-1:2016 ISO ePM1
Exhaust filter according to ISO 16890-1:2016 ISO ePM10
Connection voltage 230 V
Surface protection housing Continuously galvanised
External controller required No
Device emplacement Indoor and outdoor positioning
With thermal overload protection Yes
Type of speed control Continuously variable
Air volume, unloaded 1141.2 m³/h
Type of heating coil None
Type of exhaust fan Direct
Power consumption 0.46 kW
Suitable for frequency control No
Frost protection circuit Yes
Pole-reversible No
Explosion safety None
Type of cooling coil None
Suitable for transformer control No
Suitable for electronic control Yes
Type of supply fan Direct
Max. air temperature 40 °C
Change-over system No
With humidifier No
Nominal duct width of suction end 500 mm
Connection suction side Rectangular
Nominal duct width, delivery side 500 mm
Number of connections delivery side 2
Nominal duct height of suction end 300 mm
Connection delivery side Rectangular
Nominal duct height, delivery side 300 mm
Number of connections suction side 2