Orcon HRC 300 MaxComfort 300m³/h at 150Pa
The new HRC 300 MaxComfort is the new MVHR unit from Orcon and replaces the HRC BRPH-15. The HRC MaxComfort is up to 60% more energy efficient than its predecessor, with a thermal efficiency of 99.3%! The unit has a maximum flow rate of 300 m³/h at 150Pa and is very quiet. In addition, the Orcon MaxComfort comes with an integrated preheater as standard.
TIP: The MVHR unit can be set to 300m³/h at 200 Pa using the dip switches.
Orcon's MVHR unit is one of the smartest heat recovery units on the market. Thanks to the many integrated sensors, the device measures the living conditions precisely and can anticipate them. This demand-controlled ventilation prevents unnecessary energy consumption. The HRC 300 comes with the following integrated sensors:
- 3 humidity sensors
- 8 temperature sensors
- 2 anemometer sensors
Thanks to the 13 built-in sensors, the flow can be balanced with an accuracy of 1%. The sensors also ensure even better regulation in different demand-controlled scenarios such as bypass, frost, shower and cooking programs. In addition, up to 20 additional RF sensors or RF controls can be connected to the unit.
The Orcon 300 MaxComfort MVHR is exceptionally easy to install. The unit is suitable for both left and right assembly by mounting the control, filters and front plate on the other side of the unit. In addition, the ventilation ducts can be connected to either the side and or the top. The device is supplied without plug.
Left and right version
There are two ways of connecting the Orcon HRC MaxComfort. The unit comes in the "left" version by default. The dwelling connections are on the left, and the connections to the outside are on the right. But this can be easily adjusted: if the front and back are detached, the unit can be turned over! For further information, consult the installation manual.
Other properties Orcon HRC 300 Healthline MaxComfort:- Includes preheater
- Latest EBM-papst 3D scrolls with Radical impellers and intelligent anemometer technology
- With humidity sensor as standard
- Best balancing technique accurate to 1%
- Highly insulating EPP housing Filter indicator
Brand | Orcon |
Category | Heat recovery choice aid |
GTIN | 8718403860115 |
Manufacturer's item number | 22000085 |
Article number | 19220030 |
Specifications
Connection diameter | 150 mm |
Connection | Male |
Connection 0-10V | No |
Airflow bij 150 Pa | 300 m³/h |
Airflow at 200 Pa | 300 m³/h |
App controllable | No |
Breedte | 760 mm |
Cos. phi according to EPN standard | 0,5 |
Roof connection top | Yes |
Roof connection side | Yes |
Depth | 600 mm |
Digital display | Yes |
Home automation connection | No |
Wireless control | Yes |
Enthalpy changer | No |
Filter class | EU 4 (G4) |
Direct current motor | Yes |
Suitable for boiler connection | No |
Hoogte | 880 mm |
Flow rate high at 100 Pa | 300 m³/h |
Flow rate high at 150 Pa | 300 m³/h |
Flow rate high at 200 Pa | 300 m³/h |
Maandactie | No |
Housing material | Plastic |
With VOC-sensor | No |
With bypass | Yes |
With built-in CO2-sensor | No |
With built-in temperature sensor | Yes |
With thermal protection | Yes |
With heating battery | Yes |
With humidity sensor | Yes |
Mounting for | Wall |
Mounting for | Assembly chair |
Power consumption according to EPN standard | 0.027 |
Ceiling mounting | No |
Thermal efficiency according to EPN standard | 99.3 % |
Plug | Peripheral ground |
Type of speed control | Other |
Floor mounting | Yes |
Wall mounting | Yes |
House connection top | Yes |
House connection bottom | No |
House connection left | Yes |
House connection right | Yes |
Zone control | 1 Zone |